Eaton Vickers SV-10-C-0-12DG
Flow Control Valve
Eaton industrial valves consistently deliver superior performance across stationary and mobile hydraulic applications. From press to bore, clamp to cut, lift to dig and beyond, they provide reliable operation even under extreme conditions.
Danfoss industrial valves and systems are designed with durability and reliability in mind, withstanding challenging operating conditions and delivering consistent performance across industrial applications.
In the de-energized position the valve blocks flow from port 2 to 1 and free flow is allowed from port 1 to 2. When the solenoid is ener-gized the pilot poppet is pulled off the seat allowing the valve to open in both directions. Features Hardened and ground work-ing parts. Lapped seat for low leakage. IP69K Tough coil com-patibility. Continuously rated. Compact design with low pressure drop.
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F)
Typical Application Pressure (All Ports): 210 bar (3000 psi)
Cartridge Fatigue Pressure (Infinite Life): 210 bar (3000 psi)
Rated Flow: 45L/min (12 USgpm)
Internal Leakage: 5 drops/min Maximum @ 210 Bar (3000 psi)
Standard Housing Materials: Aluminum
Temperature Range: -40° to 120°C (-40° to 248°F)
Coil Duty: Continuous from 85% to 110% of nominal voltage
Fluids: All general purpose hydraulic fluids such as: MIL–H–5606, SAE 10, SAE 20, etc.
Filtration Cleanliness Code: 18/16/13
Seal Kit: 565803 Buna–N / 566086 Viton
Weight: 0.47 kg (0.86 lbs)
Coil Technical Details
Series: J Series
Power: 20 Watt
Voltage: 12VDC
Duty Rating: Continuous from 85% to 110% of nominal voltage
Hazardous Environmental Rating: Yes
Pressure Level Valve Control: 210
Weight: 0.27 kg (0.60 lbs)
Can't Find A Part? Ask us!